MCF Lite Series : Consumer Electronics and Wearable Device Battery Test Equipment
Intro:
MCF Lite satisfies the research and testing needs of consumer electronics, wearable devices, and battery materials. The battery cycle tester supports μA level current output and provides two ranges of current output settings to increase test flexibility. Users select the applicable range of current based on the requirements and testing phases and maintain consistent precision. The system uses an compact system architecture design that offers great economic benefits.
- Support two ranges current settings, 500mA/50mA or 3A/300mA, to enhance flexibility and improve precision.
- The current settings can reach as low as 50uA, meeting the requirements for tiny battery testing.
- System controller can simultaneously manage 8 channels, and each channel operates independently.
Model | MCF Lite Series |
AC Power | Customized According To Client Needs |
Loading RangeCharge Discharge | 0~7V 0~7V |
Constant VoltageMaximum Resolusion Accuracy | Depend on Spec* 16 bit ±0.075% F.S. |
Constant CurrentMaximum Multiple Ranges Resolusion Accuracy | Depend on Spec* 2 (Dual Model) 16 bit ±0.06% F.S. |
Constant PowerMaximum Resolusion Accuracy | Depend on Spec* 16 bit ±0.14% F.S. |
Data Recording Time | 1s |
Communication Interface | Ethernet |
Ambient | 23°C±2°C; 20~90 HR |
Optional Features | DCIR Measurement、ACIR Measurement、Chamber Integration、Data Analyzer、Automated/semi-automated activation |
Accessory | Chamber、Customized Fixture、Alarm Buzzer、Auto-Calibrator、Barcode Scanner |
*Accept customized request
Model | Voltage(V) | Current (A) | |
Range 1 | Range 2 | ||
MCF Lite Single 2V/0.05A | 2 | 0.05 | X |
MCF Lite Single 2V/0.3A | 2 | 0.3 | X |
MCF Lite Single 2V/0.5A | 2 | 0.5 | X |
MCF Lite Single 2V/3A | 2 | 3 | X |
MCF Lite Single 5V/0.05A | 5 | 0.05 | X |
MCF Lite Single 5V/0.3A | 5 | 0.3 | X |
MCF Lite Single 5V/0.5A | 5 | 0.5 | X |
MCF Lite Single 5V/3A | 5 | 3 | X |
MCF Lite Single 7V/0.05A | 7 | 0.05 | X |
MCF Lite Single 7V/0.3A | 7 | 0.3 | X |
MCF Lite Single 7V/0.5A | 7 | 0.5 | X |
MCF Lite Single 7V/3A | 7 | 3 | X |
MCF Lite Dual 2V/0.5A | 2 | 0.5 | 0.05 |
MCF Lite Dual 2V/3A | 2 | 3 | 0.3 |
MCF Lite Dual 5V/0.5A | 5 | 0.5 | 0.05 |
MCF Lite Dual 5V/3A | 5 | 3 | 0.3 |
MCF Lite Dual 7V/0.5A | 7 | 0.5 | 0.05 |
MCF Lite Dual 7V/3A | 7 | 3 | 0.3 |
DCIR Measurement
High-power battery module DC internal resistance
ACIR Measurement
High-power battery module AC internal resistance
Chamber Integration
The synchronous control of chambers can be achieved during the testing processes.
Temperature and humidity levels can be adjusted to simulate different environments for measuring the battery’s performance.
Automated/semi-automated activation
Advanced Data Analysis
With advanced data analysis feature, a variety of test data presentations could be adjusted according to the needs of researchers, such as text and graphical reports, self-defined X and Y-axis parameters on graphs and graphs zoom-in / zoom-out. It also helps researchers to easily analyze the data from cycle test. Data from each cycle can be superimposed and drew on a single chart to produce a lifecycle test report. Evaluating test results and finding variation are easy! Moreover, test data can be exported in csv format and manipulated in the third-party software that researchers are familiar with, improving the data usability.
Universal/ Customized Fixture
According to customer requests, CTE provides a variety of universal fixtures and customized fixtures.The universal fixture is specially designed for cylindrical and prismatic batteries. It is suitable for a wide range of battery specifications, and can be adjusted by customers to work with the batteries to be tested. The non-base plate design allows the battery to be lifted, reducing the thermal impact on battery test. Moreover, the removable battery compartment also makes changing battery convenient and flexible. For customized fixtures, please contact Chen Tech Electric.
Universal Fixture Application | Cylindrical and Prismatic Batteries |
Suitable Battery Size (mm) | 18~100W*52D*55H |
Number of Battery Holders | 4~24 |
Loadable Current | Under 40A |
MaterialsOuter Frames Battery Box | Stainless Steel Bakelite |
Size (mm)Main Body Battery Box | 340W*423D*586H 319W*85D*239H |
Auto Calibrator ACP2 Series
ACP is especially designed to improve the efficiency and precision of calibration for CTE test equipment. It is applicable for CTE equipment with maximum voltage under 20V and maximum current lower than 100A. Its flexible and scalable design can be expanded to include up to 8 meters, thus ACP is capable of calibrating 8 testing channels simultaneously, which greatly reduces labor cost and time. Also, removable shunts and meters are built-in, making it easy to calibrate and maintain.
Model | ACP2 L Series | ACP2 N Series | ACP2 M Series | ACP2 B Series |
AC Power | AC110/220V | AC110/220V | AC110/220V | AC110/220V |
Applicable Spec | 20V/1A and less | 20V/3A~20A and less | 20V/20A~50A and less | 20V/50A~100A and less |
Applicable | MCF Lite Series MCL2 Mini Series BT 2000 Series MCP Plus Series | MCB Series MCL2 Series MCL2 Mini Series ABT 1000 Series GBT 1000 Series BT 2000 Series MCP Plus Series | MCB Series MCL2 Series ABT 1000 Series BT 2000 Series MCP Plus Series | MCB Series MCL2 Series ABT 1000 Series BT 2000 Series MCP Plus Series |
Alarm Buzzer
Barcode Scanner
Chamber
We collaborate with several 3-rd party chamber manufacturers such as Espec, Terchy, Giant Force, and TATO, and integrate their products into our system. Thus, users are capable of controlling chamber directly with iBest software.