GBT 1000 Series : Telecom Device Battery Test Equipment
Intro:
GBT 1000 is designed for testing batteries commonly used in mobile electronic devices. It applies high-speed pulse discharge to valid battery performance. The high-speed current response time not only allows for precise control of pulse duration, but also meets the international testing standards.
- Support 8-phase pulse charge/ discharge with independent duration and current settings (in line with international pulse standards such as GSM and PWM)
- Precisely record the pulse current and voltage variations of every phase
Model | GBT 1000 Series |
AC Power | Customized According To Client Needs |
Loading RangeCharge Discharge | 0~20V* 2~20V*(Option: Discharge to 0V) |
Constant VoltageMaximum Resolusion Accuracy | Depend on Spec* 16 bit ± 0.02% F.S. |
Constant CurrentMaximum Resolusion Accuracy | ± 10A* 16 bit ± 0.02% F.S. |
Constant PowerMaximum Resolusion Accuracy | Depend on spec 16 bit ± 0.04% F.S. |
Data Recording Time | 100ms (1s in GSM mode) |
Ambient | 23°C±2°C; 20~90 HR |
Pulse TimeMaximum Pulse Width Minimun Pulse Width Resolution | 60s 500μs 50μs |
Communication Interface | Ethernet |
Ambient | 23°C±2°C; 20~90 HR |
Optional Features | DCIR Measurement、ACIR Measurement、Chamber Integration、Data Analyzer、BMS & Gas Gauge Data Collection |
Accessory | BMS & Gas Gauge Data Collector、Auxiliary Voltage、Auxiliary Temperature、Chamber、Customized Fixture、Auto-Calibrator、Alarm Buzzer |
*Accept customized request
Model | Voltage(V) | Current (A) |
GBT 1000 5V/10A | 5 | 10 |
GBT 1000 20V/10A | 20 | 10 |
DCIR Measurement
High-power battery module DC internal resistance
ACIR Measurement
High-power battery module AC internal resistance
Chamber Integration
BMS & Gas Gauge Data Collection
During battery modules/ packs testing, the Gas Gauge/ BMS data is retrieved and recorded.
The data obtained can be used as the condition for program step change or providing protection.
1. Supports communication protocols such as SMBus, I2C, HDQ etc. for IT batteries and Modbus, CANBus etc. for power batteries.
2. Supports CAN .dbc file editing and import.
Advanced Data Analysis
With advanced data analysis feature, a variety of test data presentations could be adjusted according to the needs of researchers, such as text and graphical reports, self-defined X and Y-axis parameters on graphs and graphs zoom-in / zoom-out. It also helps researchers to easily analyze the data from cycle test. Data from each cycle can be superimposed and drew on a single chart to produce a lifecycle test report. Evaluating test results and finding variation are easy! Moreover, test data can be exported in csv format and manipulated in the third-party software that researchers are familiar with, improving the data usability.
BMS & Gas Gauge Data Collector
GDA 300 records the static/ dynamic parameters of the BMS in energy/ power batteries. It supports SMBus, I2C, HDQ, Modbus, CANbus and other communication protocols that are commonly used in energy and power batteries, and it is scalable. With GDA 300, users are allowed to define customized parameters as step cutoff condition while running battery test. Additional parameters can also be defined by researchers to collect and analyze advanced data.
Model | iBox - G | GDA-300 |
CH/ per Unit | 8CH | 4CH |
CH/ per System | 256CH | 128CH |
Mechanism Design | Rack/ Portable | Rack/ Portable |
Communication Protocols (Battery) | SMBus/ I2C / HDQ | SMBus/ I2C / HDQ |
Communication Protocols (PC) | Ethernet/ Wifi | RS-485 |
Communication Speed | 2Sec / 8CH* | 5Sec / 16CH |
Number of parameters | 47 | 47 |
Temperature Classification | 0~60°C | 0~60°C |
SmartCHarge | Yes | Yes |
SBS Write | Yes | Yes |
Gauge Condition | Yes | Yes |
*iBox-G only
*Depend on chosen thermal sensors
Auxiliary Voltage/ Auxiliary Temperature
Auxiliary voltage and auxiliary temperature are for collecting the voltage and temperature data of a single cell in the battery pack. Collected data can be used as step cutoff conditions while running the battery test, improving the flexibility of the production line and laboratory.
Model | Auxiliary Voltage ES-100B |
Channels | 24 |
Measurement Range | ±64V,±32V,±8V |
Measurement Resolution | 16 bit |
Accuracy | 0.02% F.S. |
Data Recording Time | 100ms (24CH) |
Model | Auxiliary Temperature ET-100B |
Channels | 24 |
Measurement Range* | -50°C~125°C |
Measurement Resolution | 0.1°C |
Accuracy | ±1°C (-40°C~90°C) |
Temperature Sensor | Thermistor |
Supported Type | 103JT |
Data Recording Time | 100ms (24CH) |
Model | Auxiliary Temperature ET-100C | |||
Channels | 16CH | 8CH | 8CH | 16CH |
Scanning Speed | 4CH/s (16CH/4s) | 4CH/s (16CH/4s) | 4CH/s (16CH/4s) | 4CH/s (16CH/4s) |
Accuracy | ±1°C | ±1°C | ±1°C | ±1°C |
Resolution | 0.1°C | 0.1°C | 0.1°C | 0.1°C |
Temperature Sensor | Thermocouple | RTD | Thermistor | Diode |
Supported Type | Type J, K, E, N, R, S, T, B | PT-10, PT-50, PT-100, PT-200, PT-500, PT-1000, NI-120 | 44004 2.252kΩ, 44005 3kΩ, 44007 5kΩ,44006 10kΩ, 44008 30kΩ | 3904 |
Measurement Range* | -265~800°C | -200~800°C | -40~150°C | -60~130°C |
*Depend on chosen thermal sensors
Universal/ Customized Fixture
According to customer requests, CTE provides a variety of universal fixtures and customized fixtures.The universal fixture is specially designed for cylindrical and prismatic batteries. It is suitable for a wide range of battery specifications, and can be adjusted by customers to work with the batteries to be tested. The non-base plate design allows the battery to be lifted, reducing the thermal impact on battery test. Moreover, the removable battery compartment also makes changing battery convenient and flexible.For customized fixtures, please contact Chen Tech Electric.
Universal Fixture Application | Cylindrical and Prismatic Batteries |
Suitable Battery Size (mm) | 18~100W*52D*55H |
Number of Battery Holders | 4~24 |
Loadable Current | Under 40A |
MaterialsOuter Frames Battery Box | Stainless Steel Bakelite |
Size (mm)Main Body Battery Box | 340W*423D*586H 319W*85D*239H |
Auto Calibrator ACP2 Series
ACP is especially designed to improve the efficiency and precision of calibration for CTE test equipment. Its flexible and scalable design can be expanded to include up to 8 meters, thus ACP is capable of calibrating 8 testing channels simultaneously, which greatly reduces labor cost and time. Also, removable shunts and meters are built-in, making it easy to calibrate and maintain.
Model | ACP2 L Series | ACP2 N Series | ACP2 M Series | ACP2 B Series |
AC Power | AC110/220V | AC110/220V | AC110/220V | AC110/220V |
Applicable Spec | 20V/1A and less | 20V/3A~20A and less | 20V/20A~50A and less | 20V/50A~100A and less |
Applicable | MCF Lite Series MCL2 Mini Series BT 2000 Series MCP Plus Series | MCB Series MCL2 Series MCL2 Mini Series ABT 1000 Series GBT 1000 Series BT 2000 Series MCP Plus Series | MCB Series MCL2 Series ABT 1000 Series BT 2000 Series MCP Plus Series | MCB Series MCL2 Series ABT 1000 Series BT 2000 Series MCP Plus Series |
Alarm Buzzer
Chamber
We collaborate with several 3-rd party chamber manufacturers such as Espec, Terchy, Giant Force, and TATO, and integrate their products into our system. Thus, users are capable of controlling chamber directly with iBest software.